ProTherm-G-featured

ProTherm XPS X ULTRA 300 SL

DESCRIPTION

ProTherm XPS X ULTRA 300 SL Inverted Roof Insulation is a unique rigid, closed cell type extruded polystyrene board with integral high density skin. ProTherm XPS X ULTRA 300 SL Inverted Roof Insulation utilises infra-red blocking particles to scatter and reflect heat radiation.

ProTherm XPS X ULTRA 300 SL Inverted Roof Insulation has a Zero Ozone Depletion Potential (ODP), a Global Warming Potential (GWP) of less than 5. For use with Inverted Roof Waterproofing such as PermaQuik PQ6100, EshaFlex, EshaUniversal, ParaFlex FD and ReadySeal. Use with ProTherm XPS X MK Filter/Water Flow Reducing Layer prior to the installation of paving, ballast or green roof.

For a comprehensive NBS J31 specification contact Radmat Building Products.

SUITABLE APPLICATIONS

ProTherm XPS X ULTRA 300 SL is suitable for use in roofs, roof terraces, enclosed balconies over heated space and insulated walkways in an inverted roof construction. When used in the inverted roof applications listed in the Fire Performance section below roof assemblies incorporating ProTherm XPS X ULTRA 300 SL achieve Broof(t4) Classification to BS EN 13501-5 as required by Approved Document B 2019 edition, Section B4, Limitations on roof coverings. ProTherm XPS X ULTRA 300 SL is not suitable for use in inverted roof applications on specified attachments such as projecting open balconies, projecting enclosed balconies, recessed open balconies or recessed enclosed balconies. ProTherm XPS X ULTRA 300 SL is not suitable for use in warm roof applications (where the waterproofing is installed above the insulation board).

CERTIFICATES

BBA Certificate No. 21/5952, ISO 9001:2008 Quality Management System, ISO 14001:2004 Environmental Management System, EPD as per ISO 14025 and EN 15804.

FIRE PERFORMANCE

As a roofing system for roofs, roof terraces, enclosed balconies over heated space and insulated walkways
In accordance with Annex of Commission Decision 2000/553/EC, when used in an inverted roof specification including an inorganic covering of either loose laid gravel with a thickness of at least 50mm or a mass ≥ 80 kg/m², sand/cement screed to a thickness of at least 30mm, or cast stone or mineral slabs of at least 40mm thickness a roof system incorporating ProTherm XPS X ULTRA 300 SL can be considered to be unrestricted under the national Requirements (Classification Broof(t4) to BS EN 13501-5:2016).

BS EN 13501-5:2016 – When tested with a covering of 50mm thick paving on InStar plastic pedestal supports, or 50/75mm ballast, or Profildeck aluminium framing on supports with 20mm Porcelain Paving a roof construction incorporating ProTherm XPS X ULTRA 300 SL achieved a classification of Broof(t4) and as such is unrestricted by the National Building Regulations.

BS 476 Part 3: 2004 – When tested with a covering of 50mm thick paving on InStar plastic pedestal supports, 50/75mm ballast, Profildeck aluminium framing with 20mm Porcelain Paving, or Dura Deck Resist Composite Deck on supports with 50mm 20/40mm ballast a roof construction incorporating ProTherm XPS X ULTRA 300 SL achieved a classification of EXT.FAA and as such is unrestricted by the National Building Regulations.

As a product in isolation
BS EN 13501-1:2016 – ProTherm XPS X ULTRA 300 SL Inverted Roof Insulation contains PolyFR, a REACH compliant flame retardant, that ensures Euro Class E performance.

ProTherm XPS X ULTRA 300 SL Inverted Roof Insulation contains PolyFR, a REACH compliant flame retardant, that ensures Euro Class E performance to EN13501-1.

Hexabromocyclododecane (HBCD) was phased out prior to the 21st August 2015.