T: 01858 410 372
E: techenquiries@radmat.com
sales@radmat.com

Insulation

Inverted Roof Insulation

ProTherm G XENERGY SLP

DESCRIPTION

ProTherm G XENERGY SLP Inverted Roof Insulation is a unique rigid, closed cell type Extruded polystyrene board with integral high density skin. ProTherm G inverted roof insulation utilises infra-red blocking particles to scatter and reflect heat radiation. 

ProTherm G XENERGY SLP Inverted Roof Insulation has a Zero Ozone Depletion Potential (ODP), a Global Warming Potential (GWP) of less than 5 and a Green Guide to Specification A+ rating.

For use with Inverted Roof Waterproofing such as PermaQuik PQ6100, EshaFlex, EshaUniversal and ParaFlex.

Use with ProTherm XENERGY MinK Water Flow Reducing Layer prior to the installation of paving, ballast, a green roof or timber decking.

All installation to be according to guidelines and specifications supplied by Radmat.

For a comprehensive NBS J31 specification contact Radmat Building Products.

APPLICATION

Apply ProTherm G XENERGY SLP Inverted Roof Insulation parallel to roof perimeter long edges. Stagger end joints.

LayProTherm G XENERGY SLP Inverted Roof Insulation with edges in moderate contact without forcing.

Cut ProTherm G XENERGY SLP Inverted Roof Insulation to fit neatly to perimeter blocking and around penetrations through roof, when using a 2nd layer stagger joints of insulation from first layer.

Apply no moreProTherm G XENERGY SLP Inverted Roof Insulation than can be covered with aggregate ballast/concrete roof pavers/green roofing in the same day.

Keep ProTherm G XENERGY SLP Inverted Roof Insulation to a minimum 75mm from heat emitting devices, and minimum 50mm from sidewalls of chimneys and vents.

Before applying the chosen roof finish install ProTherm G XENERGY MinK Water Flow Reducing Layer over the ProTherm G XENERGY SLP Inverted Roof Insulation ensuring Radmat standard details are adhered to and all overlaps are 300mm wide.

FIRE PERFORMANCE

ProTherm G XENERGY SLP Inverted Roof Insulation contains PolyFR, a REACH compliant flame retardant, that ensures Euroclass E performance to EN13501-1. Hexabromocyclododecane (HBCD) was phased out prior to the 21st August 2015.

 

Description  Value
Appearance Grey Skin
Board Width 600mm
Board Thickness 50/80/100/120/130/140/160/180/200/205mm
Board Length 1250mm
Edge Profile Shiplap
Thermal Conductivity 0.031 W/mK
Certificates BBA No. 17/5397
Downloads
BBA ProTherm
BBA PermaQuik
DoP ProTherm G XENERGY SLP
PDS ProTherm G XENERGY SLP
SDS ProTherm G XENERGY SLP

Click on the items above to view or download information. To download multiple items as a zip file click + to add to a collection.

Please Login before adding files to a collection.